Three Phase Air Cooled Chiller

Three Phase Air Cooled Chiller
Three Phase Air Cooled Chiller

Three Phase Air Cooled Chiller Specification

  • Application
  • Industrial and Commercial Cooling
  • Motor
  • Three Phase Induction Motor
  • Material
  • Mild Steel Body with Powder Coating
  • Refrigerating Capacity
  • 12 TON (42 kW)
  • Air Flow
  • 3000 m/h
  • Condition
  • New
  • Type
  • Air Cooled Chiller
  • Dimension (L*W*H)
  • 1600 x 900 x 1400 mm
  • Power Supply
  • Three Phase, 50/60 Hz
  • Voltage
  • 380-415V
  • Cooling Type
  • Air Cooled
  • Nozzle Material
  • Brass
  • Cooling Coil Material
  • Copper with Aluminium Fins
  • Water Flowing Rate
  • 3.6 m/h
  • Water Pump Motor
  • 1.5 HP
  • Noise Control
  • Low Noise Operation <65 dB
  • Compressor
  • Hermetically Sealed Scroll Compressor
  • Evaporator
  • Shell & Tube Type
  • Ambient Operating Range
  • 5°C - 45°C
  • Condenser
  • Fin & Tube Type
  • Display
  • Digital Display Panel
  • Chilled Water Outlet Temperature
  • 7°C
  • Temperature Control
  • Microprocessor Based Controller
  • Refrigerant
  • R407c/R134a
  • Pump Type
  • Centrifugal Pump
  • Customization
  • Available as per Requirement
  • Protection Devices
  • Overload, Phase Reversal, High/Low Pressure Cutout
  • Cooling Capacity Range
  • 5TR to 100TR
  • Installation Type
  • Floor Mounted
  • Portability
  • Caster Wheels for Easy Movement
 

Three Phase Air Cooled Chiller Trade Information

  • Minimum Order Quantity
  • 1 , , Unit
  • Supply Ability
  • 1 , , Unit Per Week
  • Delivery Time
  • 1 Week
 

About Three Phase Air Cooled Chiller

Specification

Tonnage

10 TR

Brand

MS Cool Engineers

Type

Air-Cooled

Voltage

440 V

Model Name/Number

MSCE 10 TR

Refrigerant Used

R 22

Phase

Three

Automation Grade

Automatic

No Of Compressor

1

Usage/Application

Industrial

Country of Origin

Made in India

Frequency

50/60 Hz

Surface Finish

Color Coated

Chiller Type

Air Cooled

 



Advanced Cooling with Precision Control

The chiller utilizes a microprocessor-based controller for accurate temperature regulation and stability, ensuring consistent chilled water output at 7C. Its digital display panel provides real-time operational data, making monitoring and adjustments straightforward.


Durable Construction for Demanding Environments

Built from powder-coated mild steel and equipped with copper coils and aluminium fins, the unit is resistant to corrosion and wear. The floor-mounted setup, complemented by caster wheels, offers both stability and mobility for flexible installations.


Customized for Indian Industrial Applications

Manufactured to order, the chiller can be adapted to specific project requirements, including cooling capacity, material preference, and application scope. Designed to withstand Indian ambient conditions (5C - 45C), it is ideal for both dealers and end-users.

FAQ's of Three Phase Air Cooled Chiller:


Q: How does the microprocessor-based controller benefit the operation of the air-cooled chiller?

A: The microprocessor-based controller ensures precise temperature management, quick response to load changes, and automatic protection against faults. This results in stable and efficient cooling, reduced energy consumption, and enhanced equipment life.

Q: What are the installation requirements and is the chiller portable?

A: Installation is floor-mounted and straightforward, requiring a three-phase power supply (380-415V, 50/60 Hz). Caster wheels allow for easy movement, so the chiller can be relocated within the facility as needed.

Q: When is it ideal to use this chiller in industrial or commercial setups?

A: This chiller is best deployed for cooling processes, equipment, or spaces where reliable temperature control is critical, particularly in ambient temperatures ranging from 5C to 45C.

Q: Where can I purchase or customize this air-cooled chiller in India?

A: The chiller is available through dealers, distributors, manufacturers, suppliers, traders, and wholesalers across India. Customization options are provided to meet specific project requirements.

Q: What protection features help safeguard the unit during operation?

A: To ensure safety and reliability, the chiller incorporates overload, phase reversal, and high/low pressure cutouts, which protect both the compressor and other essential components from damage.

Q: How does the air-cooled chiller maintain low noise levels?

A: The design includes efficient components and sound-dampening features, keeping operational noise below 65 dB, making it suitable for environments with strict noise control requirements.

Q: What advantages does this chiller offer over other types?

A: This model combines high efficiency, customizable capacity (5TR to 100TR), easy mobility, robust construction, and comprehensive safety features, providing a versatile and dependable cooling solution for various industrial and commercial applications.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email



Back to top