250 TR FRP Cooling Towers

250 TR FRP Cooling Towers
250 TR FRP Cooling Towers

250 TR FRP Cooling Towers Specification

  • Air Flow
  • 96000 CFM
  • Refrigerating Capacity
  • 250 TR (Tons of Refrigeration)
  • Application
  • Industrial/HVAC/Process Cooling
  • Material
  • FRP (Fibre Reinforced Plastic)
  • Motor
  • 7.5 HP, 3 Phase
  • Condition
  • New
  • Type
  • Induced Draft, Counter Flow
  • Dimension (L*W*H)
  • 2500 mm x 2500 mm x 2650 mm (Approx.)
  • Power Supply
  • 3 Phase AC, 50 Hz
  • Voltage
  • 415 V
  • Cooling Type
  • Wet Cooling
  • Nozzle Material
  • Polypropylene (PP)
  • Cooling Coil Material
  • PVC/Fibre-glass Structured Fill
  • Water Flowing Rate
  • 750 LPM
  • Water Pump Motor
  • Not Included (External pump required)
  • Noise Control
  • 65 - 70 dBA @ 1 meter
  • Compressor
  • Not Applicable (For Cooling Tower Application)
  • Structure
  • Hot Dip Galvanized Steel or FRP Casing
  • Weight (Approx.)
  • 1200 kg
  • Usage
  • Continuous Industrial/Domestic Use
  • Inlet/Outlet Connection
  • Flanged
  • Fill Type
  • Honeycomb (PVC)
  • Water Distribution
  • Rotary Sprinkler with PVC/PP Nozzles
  • Fan Diameter
  • 1400 mm
  • Fan Type
  • Dynamically Balanced Aluminium Axial Fan
  • Maintenance
  • Corrosion-resistant, Low Maintenance Design
  • Temperature Range
  • Inlet 37°C, Outlet 32°C (Design Conditions)
  • Drift Loss
  • Less Than 0.02% Of Circulating Water Flow
 

250 TR FRP Cooling Towers Trade Information

  • Minimum Order Quantity
  • 1 , , Unit
  • Supply Ability
  • 1 , , Unit Per Week
  • Delivery Time
  • 1 Week
 

About 250 TR FRP Cooling Towers

Specification

Usage/Application

Industrial

Brand

MS Cool Engineers

Tower Material

Fiberglass Reinforced Polyester

Tower Type

Induced Draft

Automation Grade

Automatic

Voltage

440 V

Frequency

50/60 Hz

Country of Origin

Made in India

Phase

Three

Surface Finish

Color Coated

Tonnage

250 TR

 



Superior Cooling Performance

Equipped with a high-capacity fan and honeycomb PVC fills, this 250 TR cooling tower ensures optimal heat rejection, meeting demanding industrial and HVAC requirements. The advanced drift eliminators restrict water loss, preserving circulating water and maintaining system efficiency.


Durable and Low-Maintenance Structure

Built with hot dip galvanized steel or FRP casing, the cooling tower resists corrosion and harsh environmental wear. Its low maintenance design, combined with a rotary sprinkler system, allows for reliable operation and reduces downtime in continuous-use applications.


Flexible Industrial and Commercial Applications

The unit supports a wide range of usage scenarios, from process cooling in factories to climate control in large facilities. With a noise control feature and compatibility with 3-phase, 415V power supply, it is suitable for new installations or system upgrades in modern industrial enterprises.

FAQ's of 250 TR FRP Cooling Towers:


Q: How does the 250 TR FRP Cooling Tower ensure efficient cooling in industrial settings?

A: The tower uses a dynamically balanced aluminium axial fan and honeycomb PVC fills to maximize air-water contact and optimize heat transfer. Its induced draft, counter flow design, paired with a rotary sprinkler system and high airflow (96,000 CFM), guarantees consistent cooling even during heavy-duty operation.

Q: What are the maintenance requirements for this cooling tower model?

A: Designed with corrosion-resistant FRP or galvanized steel casing, the tower requires minimal maintenance. The honeycomb PVC fill and drift eliminators reduce scaling and water loss, and the rotary sprinkler with PVC/PP nozzles further lowers the need for frequent cleaning or servicing.

Q: When should this cooling tower be used in process cooling or HVAC applications?

A: This 250 TR cooling tower is ideal for continuous industrial process cooling and large-scale HVAC systems whenever reliable, sustained heat rejection is essential. It operates within an inlet temperature of 37C and outlet of 32C, supporting consistent temperature control in demanding environments.

Q: Where can the 250 TR FRP Cooling Tower be installed and operated?

A: The cooling tower is suitable for both indoor and outdoor installations across India, making it versatile for factories, commercial buildings, hospitals, refineries, and other places requiring continuous cooling. Its corrosion-resistant design is built to withstand varied climates and site conditions.

Q: What is the process of water distribution in this cooling tower?

A: Water is evenly distributed using a rotary sprinkler fitted with PVC/PP nozzles, ensuring uniform coverage onto the honeycomb fill media. This arrangement maximizes thermal efficiency and aids effective cooling of reciprocating water across all operating scenarios.

Q: How does the cooling tower contribute to noise reduction?

A: Noise levels are controlled to 65-70 dBA at a 1-meter distance, thanks to the dynamically balanced axial fan and the overall well-designed airflow architecture. This allows safe usage even in noise-sensitive areas like commercial complexes or public institutions.

Q: What are the primary benefits of choosing this model for cooling applications?

A: Key benefits include robust construction, energy-efficient operation, low drift loss, minimal maintenance needs, reduced noise, and adaptable installation solutions. These features deliver cost savings, reliable performance, and longevity in industrial and professional cooling setups.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in FRP Cooling Towers Category

150 TR FRP Cooling Towers

150 TR FRP Cooling Towers

Price 1.6500000 INR / Unit

Minimum Order Quantity : 1 Unit

Motor : 7.5 HP/1440 RPM

Water Pump Motor : 10 HP/2880 RPM

Power Supply : Three Phase, 415 V, 50 Hz

Condition : New